Aizen Archistore holds no product certification and claims no certification that is not documented. Regulatory obligations (CE marking, Declaration of Performance) lie with the manufacturer for products covered by a harmonised standard. We request these documents from the manufacturers and send them with the quotation when available; their availability is confirmed reference by reference.

Framework: the Construction Products Regulation (CPR)

In the European Union, a construction product covered by a harmonised standard must, when placed on the market, be covered by a Declaration of Performance (DoP) and carry the CE marking. Regulation (EU) No 305/2011 is being progressively replaced by Regulation (EU) 2024/3110, applicable since 8 January 2026: each product family switches when a new harmonised technical specification is adopted; until then, harmonised standards cited under Regulation 305/2011 remain valid.

Outside the EU (Türkiye, Senegal…), requirements are set by national regulations and the project specifications; the manufacturer’s CE documents may be supplied for reference.

Applicability by product family

FamilyCovered by the CPR?Harmonised standards (examples)What applies
Ceramic tiles (floor and wall)Yes (CPR)EN 14411Manufacturer’s CE marking + Declaration of Performance (DoP).
Laminate, resilient or textile floor coveringsYes (CPR)EN 14041Manufacturer’s CE marking + DoP.
Wood flooring and parquetYes (CPR)EN 14342Manufacturer’s CE marking + DoP.
Wall panels and decorative coveringsDepends on the productEN 13986 (wood-based panels for use in construction)Interior decorative panels with no harmonised standard carry no CE marking under the CPR.
Windows and external pedestrian doorsYes (CPR)EN 14351-1 (+ EN 16034 for fire / smoke resistance)Manufacturer’s CE marking + DoP.
Internal doorsNo (outside CPR)No harmonised standard cited to dateNo CE marking under the CPR; fire requirements per national rules and project specifications.
Sanitaryware (WCs, urinals, basins, shower trays, baths, shower enclosures, sinks)Yes (CPR)EN 997, EN 13407, EN 14688, EN 14527, EN 14516, EN 14428, EN 13310Manufacturer’s CE marking + DoP.
Taps and mixersNo (outside CPR)No harmonised standard cited under the CPRNational drinking-water approvals may be required (e.g. ACS in France).
Kitchens (furniture, worktops)No (outside CPR)—General product safety (Regulation (EU) 2023/988).
Appliances, lighting and electrical equipmentNo (outside CPR)—Manufacturer’s CE marking under the Low Voltage 2014/35/EU, EMC 2014/30/EU and RoHS 2011/65/EU directives.
Power cables permanently installed in buildingsYes (CPR)EN 50575CE marking + DoP (reaction to fire).
Photovoltaic solar panelsNo (outside CPR)—Manufacturer’s CE marking (Low Voltage, EMC). Any IEC test reports are manufacturer documents, not a certification held by Aizen Archistore.
Building materials (cements, plasterboard, insulation, sealants, tile adhesives…)Yes (CPR)EN 197-1, EN 520, EN 13162 to EN 13171, EN 15651, EN 12004Manufacturer’s CE marking + DoP.
Modular buildingsDepends on the product—The CPR does not apply to a building as such; its components may be covered. Permits and building rules of the destination country apply.
Spa, sauna and wellnessNo (outside CPR)—Manufacturer’s CE marking for electrical equipment (Low Voltage, EMC).
Building hardwareDepends on the productEN 179, EN 1125, EN 1154, EN 1935 (fire / escape doors)CE marking + DoP for these uses; decorative handles (EN 1906, not harmonised) carry no CE marking under the CPR.

General, non-exhaustive information. Exact applicability depends on the product and its intended use; it is confirmed with the manufacturer’s documentation at quotation stage.

Request a product’s documentation